4-42

DAS ACI Functions

601626-B

aci_eject2

The aci_eject2 function ejects a range of volumes from the
AML. See Figure 4-34.

Figure 4-34

aci_eject2 Function Call

For the structure of the aci_ei_info function, refer to
Figure 4-35.

Figure 4-35

Structure of the aci_ei_info function from aci.h

See Table 4-16 for a description of the parameters for the
aci_eject2 function call.

Table 4-16

Parameters for the aci_eject2 Function Call

Parameter

Description

eject_area

logical area defined in the AMS, where the cartridges should be
ejected

volser_range

• a single volser
• multiple volsers separated by commas
• a range of volsers separated by a hyphen
• set to empty (““ or ‘\0’) if it is not to be changed

type

media type of the named volser range
Refer to Media Types on page 2-7

pnActualCount

returned number of ejected volsers

#include "aci.h"

int aci_eject2( char *eject_area,

char *volser_range,

enum aci_media type,

int *pnActualCount,

struct aci_ei_info *psteiInfo)

struct aci_ei_info {

char volser[ACI_VOLSER_LEN];

char media_type[ACI_DRIVE_LEN];

int errcode

};