Table 4-19, Para – ADIC Server User Manual

Page 94

Advertising
background image

4-52

DAS ACI Functions

601626-B

See Table 4-19 for a description of the parameters for the
aci_eject2_complete function call.

If the eject area is full the system stops the eject procedure.
Depending on the DAS_EJECTAREAFULL environment
variable on the AMU, the command will be canceled, or the
system starts with the next eject after the operator has
removed cartridges from the eject area.

The attribute of the coordinate will be set to empty in the
AMU database. The volser will be set to 0000000000000000,
but the type will remain unchanged. The compartment is
ready for the other volsers.

For additional information, refer to aci_insert on page 4-75,
and aci_eject2 on page 4-42.

Table 4-19

Parameters for the aci_eject2_complete Function Call

Parameter

Description

eject_area

logical area defined in AML, where the cartridges
should be ejected

volser_range

• a single volser
• multiple volsers separated by commas
• a range of volsers separated by a hyphen
• set to empty (““ or ‘\0’) if it is not to be changed

type

media type of the named volser range
Refer to Media Types on page 2-7

pnActualCount

returned number of ejected volsers

aci_ei_info

returned information to each ejected volser

volser

volser of the ejected volume

type

media type of the named volser
Refer to Media Types on page 2-7

errcode

Error code derrno

Advertising