Adding system drives, Adding system drives -6 – Acer PCI Disk Array Controller Drivers 08P4100 User Manual

Page 66

Advertising
background image

Adding System Drives

5-6

PCI Disk Array Controller Drivers Manual

Adding System Drives

The recommended method for creating UNIX file systems on System Drives
is through the SCO UNIX mkdev hd command. Follow the instructions in the
SCO UNIX documentation for adding a hard disk.

Mylex Disk Array Controllers are mapped differently under SCO UNIX than
under the Mylex Disk Array Controller Configuration Utility. It is necessary
to use the target ID and the LUN number to identify each system drive being
created for SCO UNIX.

The following table shows the relationships of SCO UNIX target IDs and
LUNs to System Drive numbers as defined under the Mylex Disk Array
Controller Configuration Utility. For example, for System Drive number 20,
enter 4 for the target ID and 3 as the LUN (shaded areas in Table 5-1).

Table 5-1. System Drive Mapping Addresses

Note

The bus number is always zero.

SCO

Target ID

Mylex Disk Array Controller Configuration Utility

System Drive Number

0

0

8

16

24

1

1

9

17

25

2

2

10

18

26

3

3

11

19

27

4

4

12

20

28

5

5

13

21

29

6

6

14

22

30

7

7

15

23

31

SCO
LUN 1

SCO
LUN 2

SCO
LUN 3

SCO
LUN 4

Y

X

Target ID

LUN ID

Advertising