Installing the Mylex Disk Array Controller as the
Secondary UnixWare Controller with UnixWare
7.x/2.1.3

If UnixWare is installed on a Mylex controller, the Mylex Disk Array
Controller driver for UnixWare is already installed in the system. Simply
install the new Mylex Disk Array Controller hardware.

Note

If you are installing UnixWare 2.1.2 as a secondary
controller, please refer to “Installing the Mylex Disk
Array Controller as the Secondary UnixWare
Controller with UnixWare 2.1.2” on page 6-8.

If UnixWare is installed on a non-Mylex controller, install the Mylex Disk
Array Controller driver for UnixWare as follows:

Note

If installing onto a system that is SISL capable and
using a SISL capable DAC it is recommended to
disable the SCSI chip driver on the system by entering
the DCU at the appropriate screen then select
Software Device Drivers and disable the appropriate
driver.

1. Insert the Software Kit UnixWare (dak) driver diskette into the floppy

diskette drive, please refer to “Creating a Driver Diskette for
UnixWare” on page 6-3.

2. Type the following (match case exactly as shown):

pkgadd -d diskette1 dak

The new controller driver is installed.

3. Rebuild the Kernel:

/etc/conf/bin/idbuild -B

4. Reboot the system:

shutdown -i0 -g0 -y