I N S TA L L AT I O N

The appliance must be installed by a qualified

service technician. The oven must be properly

grounded in accordance with the National

Electrical Code and applicable local codes.

Plug the unit into a properly grounded receptacle

ONLY, positioning the unit so that the plug is

easily accessible in case of an emergency. Arcing

will occur when connecting or disconnecting the

unit unless all controls are in the “

OFF

” position.

Proper receptacle or outlet configuration or

permanent wiring for this unit must be installed

by a licensed electrician in accordance with

applicable local electrical codes.

REGARDING INTERNATIONAL

STANDARD UNITS:

If the unit is not equipped with flexible cord

with plug, an all-pole country approved

disconnection device which has a contact

separation of at least 3mm in all poles must be

incorporated in the fixed wiring for disconnection.

When using a cord without a plug, the

green/yellow conductor shall be connected to the

terminal which is marked with the ground symbol.

If a plug is used, the socket outlet must be easily

accessible. If the power cord needs replacement,

use a similar one obtained from the distributor.
For 230V units: To prevent an electrical shock

hazard between the appliance and other

appliances or metal parts in close vicinity, an

equalization-bonding stud is provided. An

equalization bonding lead must be connected to

this stud and the other appliances / metal parts

to provide sufficient protection against potential

difference. The terminal is marked with the

following symbol.

E L E C T R I C A L C O N N E C T I O N

D A N G E R

ELECTRICAL CONNECTIONS MUST

BE MADE BY A QUALIFIED SERVICE

TECHNICIAN IN ACCORDANCE WITH

APPLICABLE ELECTRICAL CODES.

D A N G E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.

D A N G E R

ENSURE POWER SOURCE

MATCHES VOLTAGE STAMPED

ON APPLIANCE NAMEPLATE.

E L E C T R I C A L

C C - 4 8

VOLTAGE

PHASE CYCLE

/

HZ AMPS

kW

208V

(

AGCY

)

1

50/60

20

4.2

NO CORD

,

NO PLUG

230V

(

AGCY

)

1

50/60

22

5.1

240V

(

AGCY

)

1

50/60 21.17 5.1

C C - 7 2

VOLTAGE

PHASE CYCLE

/

HZ AMPS

kW

208V

(

AGCY

)

1

50/60

30

6.2

NO CORD

,

NO PLUG

230V

(

AGCY

)

1

50/60

33

7.5

240V

(

AGCY

)

1

50/60

31

7.5