Local Terminal Configuration

Using a Local Terminal

21

NOTE

The probe CONFIG button is recessed. This requires the use of a narrow, pointed
object (like a pen) to press the CONFIG button.

The probe executes a cold start if you press the CONFIG button twice within one
second. If this happens, wait for the cold start to be completed and press the
CONFIG button again to enter the configuration mode.

A warm start or cold start is completed when the Fault LED goes off. If traffic is
present, the Activity LED flashes to show traffic.

Figure 2-2: The Probe’s Main Menu

NOTE

Item 5 in Figure 2-2 is not displayed if the Allow TFTP firmware downloads
menu item is not enabled. Refer to “Modify/View Security Values” on page 24 for
more information on enabling this menu item.

If item 5 (TFTP Download new firmware) is not displayed, the number used to
access items 6, 7, and 8 will be different.

Main Menu - Revision

1. Modify/View configuration values ->

2. Modify/View security values ->

3. Modify/View interface values ->

4. Display interface summary

5. TFTP Download new firmware ->

6. XMODEM Download new firmware ->

7. Warm start and Exit

8. Cold start and Exit