Commer cial mode setup – LG 22LG3DCH User Manual

Page 103

Advertising
background image

COMMER

CIAL

MODE

SETUP

101

Menu Item

Function

Value Range

Default Value

Brief Description of Function and Comments

000

INSTALLER SEQ

0 ~ 3

0

Leave default set to 0.

001

POWER MANAGE

0 ~ 7

0

Sets number of hours of no activity before auto shut Off.

002

AC ON

0 / 1

0

Set to 1 to enable auto turn On at power up.

003

BAND/AFC

0 ~ 3

1

Selects Tuning Band: 0=Broadcast, 1=CATV, 2=HRC, 3=IRC

004

STRT CHANNEL

0 ~ 127, 255

255

Channel at turn-on (Set to 255 to tune in last channel before power Off).

005

CHAN LOCK

0 / 1

0

If set to 1, cannot tune from current channel.

007

STRT VOLUME

0 ~ 63, 255

255

Sets Volume level at TV turn-on (Set 255 to retain last volume level).

008

MIN VOLUME

0 ~ 63

0

Sets minimum allowable volume setting.

009

MAX VOLUME

0 ~ 63

63

Sets maximum allowable volume setting.

010

MUTE DISABLE

0 / 1

0

Set to 1 to disable mute function.

011

KEY DEFEAT

0 / 1

1

Set to 1 to disable menu navigation keys on TV.

012

IR BANKS EN.

0 / 1

0

Set to 1: enables TV to respond to IR code

013

SCAN MODE

0 / 1

1

Typically used for Hospitals: puts TV On-Off event in Ch Up/Down sequence.

014

STRT CH IN SM

0 / 1

0

Set to 1 to put TV On/Off below start channel number.

015

SLEEP TIMER

0 / 1

1

Set to 1 to enable Sleep Timer.

016

EN TIMER

0 / 1

1

Set to 1 to enable On/Off Timers.

017

ALARM

0 / 1

1

Set to 1 to enable Alarm.

020

FEATURE LEVEL

0 / 1

1

Zen 1 Leave default set 1 (1 Zen 1)

021

V-CHIP

0 / 1

1

Set to 1 to enable V-Chip functions.

022

MAX BLK HRS

0 ~ 99

12

Sets the number of V-Chip (Parental Control) blocking hours.

023

CAPTION LOCK

0 / 1

0

Set to 1 to retain caption setting at power Off.

025

FUNCTION PRE.

0 ~ 3

1

Controls channel preview in Pay-Per-View function

027

HOSPITAL MODE

0 ~ 2

2

Leave default set to 2.

028

CH. OVERIDE

0 / 1

1

If set to 0, limits direct access to only channels in TV memory.

029

OLD OCV

0 / 1

0

Set to 1 to change M.P.I. operation to OCV.

IIn

nssttaalllleerr M

Meen

nu

u IItteem

mss 0

00

00

0 tth

hrro

ou

ug

gh

h 2

29

9

Advertising