The DS.11 Configuration Utility

3-17

Station Control Tab

The Station Control tab enables you to revert the unit parameters to their factory
defaults, reset the unit and export the unit’s configuration to a configuration file.

Figure

3-10: The Station Control Tab

The Station Control tab is comprised of the following components:
Station Control: Click the

button for all parameters to revert to the

factory defaults.

♦ Click the

button to export the current basic configuration of this unit

to a file. A popup window is displayed prompting you to specify the name of the
file. The created file can be used to save the configuration information or to
send it to tech support as a reference for troubleshooting.

Reset Unit: Click the

button to reset the unit and apply

any changes made to the system parameters.

The flash memory can store two software versions. One version is called
Current and the other is called Shadow. New software versions are loaded as
the shadow version. You can select the shadow version as the new active
version by selecting Reset and Boot from Shadow Version. However, after the
next reset, the current version is re-activated. To continue using the currently
active version after the next reset, select Use Current Version After Reset.

The parameters configured in the unit are not changed as a result of loading
new software versions unless the new version includes additional parameters
or additional changes in the list of parameters. New parameters are loaded with
their default values.

♦ Click the

button to reset the unit and boot from the

shadow version.

♦ Click the

button to use the current running version after

the next reset.