The DS.11 Configuration Utility

3-31

Resetting the SNMP Community
Strings

The SNMP Read/Write Community strings serve as an SNMP security feature to
restrict management access to authorized persons only.

To reset the SNMP community strings, insert a paper clip or another suitable tool
into the Reset button on the top panel of the unit and press the button it for than
one second at least (see Figure

2-6 on page 2-13) while the unit is operating. After

one more second the community strings are reset to the default values, private
(Read/Write) and public (Read).

Reloading Factory Default Settings

To reset the unit to the factory defaults:

1.

Disconnect the power cable from the indoor unit.

2.

Insert a paper clip or another suitable tool into the Reset button on the top

panel of the unit (see Figure

2-6 on page 2-13). Keep the Reset button pressed

while inserting the power cable back into its socket. Keep the Reset button
pressed for at least 3 seconds after reinserting the power cable. After one more
second the unit will be reset to its factory default configuration.