Warning, Connecting electric dryers (cont.) usa only – LG DLGX6002V User Manual

Page 24

Advertising
background image

24

INSTALLATION INSTRUCTIONS

Connecting electric dryers (cont.)

USA only

W

WARNING

t$POOFDUUIFQPXFSDPSEUPUIFUFSNJOBMCMPDL&BDIDPMPSFE

wire should be connected to same color screw. Wire color
indicated on manual is connected to the same color screw
in block. Failure to follow these instructions may result in a
short or overload.

t(SPVOEJOHUISPVHIUIFOFVUSBMDPOEVDUPSJTQSPIJCJUFE

GPS  OFXCSBODIDJSDVJUJOTUBMMBUJPOT   NPCJMFIPNFT 
 SFDSFBUJPOBMWFIJDMFT BOE  BSFBTXIFSFMPDBMDPEFT
prohibit grounding through the neutral conductor.

Three-Wire Connection for Electric Dryers:
Power Cord

t"XJSFDPOOFDUJPOJT/05QFSNJUUFEPOOFXDPOTUSVDUJPOBGUFS

+BOVBSZ 

t"6-MJTUFETUSBJOSFMJFGJTSFRVJSFE

3FNPWFUIFUFSNJOBMCMPDLBDDFTTDPWFSPOUIFVQQFSCBDLPG

the dryer. Install a UL-listed strain relief into the power cord
through-hole; then thread a UL-listed,

" 7 XJSF 

"8(NJOJNVNDPQQFS conductor power cord through the
strain relief.

t6TFB" 7 6-MJTUFEQPXFSDPSEXJUI"8(

minimum copper conductor and closed loop or forked
terminals with upturned ends.

"UUBDIUIFUXPIPUMFBETPGUIFQPXFSDPSEUPUIFPVUFS

terminal block screws. Attach the neutral wire to the center
terminal block screw. Connect the external ground (if required
by local codes) to the green ground screw.

5*()5&/"--

4$3&844&$63&-:. Reinstall the terminal block access cover.

UL-Listed
Strain Relief

UL-Listed
8JSF1PXFS
Cord

Terminal
Block

Ground
Screw

Neutral
(White)

Hot

(Black)

Power Cord
Ground Wire

Hot

(Red)

Advertising