INSTALLATION INSTRUCTIONS

Installation test (Exhaust check) (cont.)

3FTUSJDUFEPS#MPDLFE"JSGMPX

Avoid long runs or runs with multiple elbows or
bends.

Excess or crushed

transition duct

Too many elbows or

exhaust too long

Check for blockages and lint buildup.

Make sure the ductwork is not crushed or restricted.

Crushed or

damaged

exhaust

t$IFDLUIF&SSPS$PEFCFGPSFZPVDBMMGPSTFSWJDF

t$IFDLUIFEVDUDPOEJUJPO

If the test displays FLOW SENSE, check the exhaust system for
restrictions and damage. Repair or replace the exhaust system as
needed.

Error Code

Possible Causes

Solutions

U&

t

Temperature sensor failure

t

Turn off the dryer and call for
service.

HS

t

Humidity Sensor failure.

t

Turn off the dryer and call for
service.

14, 1'

or

O1

t

Electric dryer power cord is not
connected correctly, or house power
supply is incorrect.

t

House fuse is blown, circuit breaker has
tripped, or power outage has occurred.

t

Check the power supply or the
connection of power cord to the
terminal block. Refer to the Connecting
Electric Dryers section of this manual
for complete instructions.

t3FTFUDJSDVJUCSFBLFSPSSFQMBDFGVTF

Do not increase the fuse capacity.
If the problem is a circuit overload,
have it corrected by a qualified
electrician.

Lint

buildup or

blockage

NOTE

When the dryer is first installed, this test should be performed
to alert you to any existing problems with the exhaust duct in
your home. However, since the test performed during normal
operation provides more accurate information on the condi-
tion of the exhaust duct than does the installation test, FLOW
SENSE displayed during the two tests may not be the same.

Do not interrupt the test cycle, as this could result in the wrong
results.

Even if FLOW SENSE is not displayed during the test cycle,
some restrictions may still be present in the exhaust system.
Refer to the Venting the Dryer section of this manual for com-
plete exhaust system and venting requirements.