4. Wiring the drain valve on the canister/

filter/pump assembly (See Drawing No.
633583, included with kit):

a. Remove drain valve motor cover on the

washer-extractor.

b. Extend 2-conductor cable already

installed on the drain valve on the
canister/pump/filter assembly to the left
drain valve on the washer-extractor.

c. Splice 2-conductor cable with the left

drain valve motor leads, using the blue
female quick-disconnect terminals
included in the kit.

Rear Panel

1/4-20 Fiberlock Nut

1/4-20 x 5/8 Screw

Recirculation

Adapter Plate

1/4-20 Fiberlock Nut

1/4-20 Fiberlock Nut

1/4-20 x 5/8 Screw

No. 48

Hose Clamp

Wet Clean Drain

Adapter Plate

1/4-20 x 5/8 Screw

1/4-20 Fiberlock Nut

Flex Drain Hose

Base Frame

Recirculation inlet hose

No. 28 Hose Clamp

Capped with Rubber Plug
Before Inlet Hose Installation

Shell

Capped with Sump
Plug Before Hose
Installation

Recirculation
Drain Outlet

Sump

Inner Drain Hose

No. 48
Hose Clamp