Level page parameters – ALESIS ANDROMEDA A6 User Manual

Page 143

Advertising
background image

Chapter 6: Modulation and Envelopes

A

NDROMEDA

A6 R

EFERENCE

M

ANUAL

141

LEVEL Page Parameters

This page of parameters is where the four levels of the envelope are set. Notice that

you can use a negative value for any or all of the levels in Envelopes 1 and 2.

DISPLAY
PAGE

PANEL LABEL

PARAMETER
DISPLAY

OPTIONS

or RANGE DESCRIPTION

LEVEL

OFFSET

-100 ··· +100

This parameter sets the fine adjustment of the

output

LEVEL

parameter, described next.

LEVEL

Output Level

0 ··· 100

This parameter sets the overall output level of
the envelope. This is also the target level of the

ATTACK

stage.

D2 LEVEL

D2LEVL

Decay 2 Level

-100 ··· +100

ENV1 & ENV2

only

0 ··· 100

ENV3 only

The target level for the

DECAY 1

slope; at this

point the

DECAY 2

time begins.

SUSTAIN

SUSTAIN

Sustain Level

-100 ··· +100

ENV1 & ENV2

only

0 ··· 100

ENV3 only

The target level for the

DECAY 2

slope; in

typical cases this is the “hold” level during a
sustain situation: a key on the A6’s keyboard is
being held down, the A6 is waiting for a MIDI
Note Off command or the end of the

GATE

from the built-in Sequencer or Arpeggiator.

R2 LEVEL

R2LEVL

Release 2 Level

-100 ··· +100

ENV1 & ENV2

only

0 ··· 100

ENV3 only

The target level for the

RELEASE 1

slope; at this

point the

RELEASE 2

time begins.

POLAR

POSWAV

NEGWAV

This parameter allows you to select between a
normal or “positive” (

POSWAV

) or inverted

(

NEGWAV

) envelope. When inverted, the

envelope is turned “upside down”: the
envelope begins at maximum level and the
Attack stage transitions to zero. The Release 2

stage transitions the level back to maximum.

This parameter is available for Envelopes 1
and 2 only. Envelope 3 is positive only:
inverting

ENV 3

would cause it to release

indefinitely at maximum level, with nothing

to stop it.

Advertising