Programming

90

TPI-PRO Total Presentation Interface - Pro Edition

"^" Button Commands (Cont.)

^BIM

Set the input
mask for the
specified address.

Syntax:

"'^BIM-<vt addr range>,<input mask>'"

Variable:

variable text address range = 1 - 4000.

input mask = Refer to the

Text Area Input Masking section on page 136 for character

types.

Example:

SEND_COMMAND Panel,"'^BIM-500,AAAAAAAAAA'"

Sets the input mask to ten ’A’ characters, that are required, to either a letter or digit (entry
is required).

^BLN

Set the number of
lines removed
equally from the
top and bottom of
a composite video
signal.

The maximum number of lines to remove is 240. A value of 0 will display the incoming
video signal unaffected. This command is used to scale non 4x3 video images into non
4x3 video buttons.

Syntax:

"'^BLN-<vt addr range>,<button states range>,<number of lines>'"

Variable:

variable text address range = 1 - 4000.

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons

1 = Off state and 2 = On state).

number of lines = 0 - 240.

Example:

SEND_COMMAND Panel,"'^BLN-500,55'"

Equally removes 55 lines from the top and 55 lines from the bottom of the video button.

Advertising