HP Air Purifier System

Grasp the handle of the filter element and pull the

filter element out of the filter housing (Fig. 4) while

it stands securely in the filter housing. You can secu-

rely grasp under filter element with both hands and

then place it down carefully.

Note: Each filter element weights approx. 16 kg.

Immediately dispose of the used filter element. Used filters capture an organic solvent (ethylene

glycol monobutyl ether acetate, CAS No. 112-07-2) and other chemicals from ink vapors. When

disposing used filter cartridges it is your responsibility to observe all local, state, and federal

regulations related to the handling, use, storage, and disposal of organic solvents.
3.3.2 IInsert tthe nnew ffilter(s)
Please, proceed as follows:

Remove the new filter element(s) from the packaging.

Store the enclosed flyer with the code in a safe place.

You will need this later to reset the service interval.

Push the filter element(s) (Fig. 5) into the filter housing

up to the stop. The surrounding gasket on the filter

element must be at the top, and the handle of the fil-

ter element must point towards the service opening.

Put the filter locking. (Fig.6)

Tighten the sealing lifting mechanism (Fig. 7) by tur-

ning the adjusting screw until it is completely tight.

Insert the screwing key into the intake again.

Close the service door until the latch engages.

Note:

Always pay attention that the surrounding gasket on the filter element(s) and on the pre-filter tray

at the top is pushed into the stop, and the adjusting screw is completely tight. Otherwise, this

can lead to leakages and the extracted gases and dust will not be filtered properly.