19

HP Air Purifier System

3.4.2 HP D

Designjet 99000s/10000s A

Air PPurifier SSystem

After replacing the filter element the service interval must be reset using the code. The following

steps must be carried out in the following order:

Switch the APS on at the membrane keyboard using the button ON/OFF. When it

switches on you will hear the fan and it will begin to extract the gases.

If "service filter" is shown in the display you must press the button "+" or "" to

suppress this fault report.

By pressing the button ENTER the programme name is displayed.

By pressing the button ENTER again "

code 1: 00000

" is displayed.

Now you can enter the code using these buttons. The code is on the flyer which is

enclosed with the new filter element.

By pressing the ENTER the actual code is saved and "

code 2: 00000

" is

displayed.

Now you can enter the code using these buttons. The code is on the flyer which is

enclosed with the new filter element.

By pressing the ENTER the actual code is saved.

If this code has been entered correctly the value for the filter contamination (middle indication

in the display) is reset to "0%" and the LED`s which may be lit or blinking extinguishes.

Note

With the HP Designjet 9000s/10000s Air Purifier System a "

code 2: 00000

" the code

from the second filter element also must be entered.

If the code 2 was not entered correctly, then also the code 1 must be entered again.