Water inlet filter, Frost precautions, Emergency emptying out – AEG LAVAMAT 86850 User Manual

Page 35

Advertising
background image

Water inlet filter

If you notice that the machine is taking longer
to fill, check that the filter in the water inlet
hose is not blocked.

1. Turn off the water tap.

2. Unscrew the hose from the tap.

3. Clean the filter in the hose with a stiff

brush.

4. Screw the hose back onto the tap.

Frost precautions

If the machine is installed in a place where the temperature could drop below
0°C, proceed as follows:

1. Close the water tap and unscrew the water inlet hose from the tap.

2. Place the end of the emergency emptying hose and that of the inlet hose in a

bowl placed on the floor and let water drain out.

3. Screw the water inlet hose back on and reposition the emergency emptying

hose after having put the cap on again

.

By doing this, any water remaining in the machine is removed, avoiding ice
forming and consequently damage to the appliance.
When you use the machine again, make sure that the ambient temperature is
above 0°C.

Emergency emptying out

If the water is not discharged, proceed as follows to empty out the machine:

1. pull out the plug from the power socket;

2. close the water tap;

3. if necessary, wait until the water has cooled down;

4. open the the pump door;

5. place a bowl on the floor and place the end of the emergency emptying hose

into the bowl. Remove its cap. The water should drain by gravity into the
bowl. Whe the bowl is full, put the cap back on the hose. Empty the bowl.
Repeat the procedure until water stops flowing out;

6. clean the pump if necessary as previously described;

7. replace the emergency emptying hose in its seat after having plugged it;

8. screw the pump again and close the door.

35

Care and cleaning

132966571.qxd 21/01/2008 16.14 Pagina 35

Advertising