Do not place the inlet hose downwards. Angle
the hose to the left or right depending on the
position of your water tap.

3. Set the hose correctly by loosening the ring nut.

After positioning the inlet hose, be sure to tighten
the ring nut again to prevent leaks.

4. Connect the hose to a tap with a 3/4” thread.

Always use the hose supplied with the appliance.

Installation should comply with local water authority
and building regulations requirements. A minimum
water pressure of 0.05 MPa is required for safe
operation of the appliance.
If you cannot make the cold water connection direct
from the rising mains, you may be able to operate the
appliance from your cold water storage system. There
should be a minimum distance of between the appli-
ance’s inlet and the bottom of the water storage tank.
The inlet hose must not be lengthened. If it is too short and you do not wish to
move the tap, you will have to purchase a new, longer hose specially designed for
this type of use.

Water-stop device

The inlet hose is provided with a water stop device,
which protects against damage caused by water leaks in
the hose which could develop due to natural ageing of
the hose. This fault is shown by a red sector in the
window “A”. Should this occur, turn the water tap off
and refer to your Service Centre to replace the hose.

Water drainage

This appliance is designed to be permanently plumbed
into your home's drainage system using one of the
following methods.

1. Into a drainage standpipe.

Firstly form a hook in the end of the drain hose using
the “U” piece” supplied.

Installation

A

352

HEC0006

P1199

“U” piece

supplied