Operating Instructions

70400101 (EN)

12

Error Codes

Display

Definition

Corrective Action

OP

Open thermistor error

• Check thermistor. Replace if inoperative.
• Check wiring diagram between control and thermistor.

Refer to wiring diagram for proper wiring.

• Check control. Replace if inoperative.

SH

Shorted thermistor error

• Check thermistor. Replace if inoperative.
• Check wiring between control and thermistor. Refer to

wiring diagram for proper wiring.

• Check control. Replace if inoperative.

AF - 1

Airflow switch closed when cycle
started

• Check airflow switch. Replace if inoperative.

AF - 2

Airflow switch failed to close after cycle
started

• Check airflow switch. Replace if inoperative.

AF

(Flashing)

Bouncing Airflow Switch

• Check airflow switch to ensure that it is properly

aligned and securely mounted in the mounting bracket.

• Make sure airflow switch can open and close freely.
• Check installation and make sure there is adequate

airflow.

• Make sure exhaust is not blocked.
• Clean the lint screen.
• Replace airflow switch if inoperative.

AF

(Solid)

Airflow Switch Closed when Resuming
Cycle

• Allow up to 20 seconds for this condition to clear.
• Check if airflow switch opens at end of cycle.
• Replace airflow switch if inoperative.

To reduce the risk of electric shock, fire, explosion, serious injury or death:

• Disconnect electric power to the tumble dryer before servicing.

• Close gas shut-off valve to gas tumble dryer before servicing.

• Close steam valve to steam tumble dryer before servicing.

• Never start the tumble dryer with any guards/panels removed.

• Whenever ground wires are removed during servicing, these ground wires must be

reconnected to ensure that the tumble dryer is properly grounded.