Operating Instructions

70400101 (EN)

14

Door Open Mode
In Door Open Mode, the control turns off the heater

and motor when the door is opened during a run cycle.

The timer will continue to count down time and the

IN USE LED is lit.
End of Cycle Mode
In End of Cycle Mode, a cycle is complete and the

IN USE LED is off. The control remains in this mode

until the door is opened or additional vend has been

satisfied
Topoffs
Any time the control receives a coin drop pulse during

a cycle it will add the programmed dry time to the time

currently remaining in the cycle. The maximum cycle

time is 99 minutes, the control will not add time

beyond 99 minutes. The cool down time will not

change.
If the control receives a coin drop pulse during cool

down the IN USE LED will flash briefly to indicate the

coin input, the machine will exit cool down and it will

start heating. The cycle time will be equal to the

programmed dry time
Temperature Selector Switch
For five minutes after the control is powered up, there

is a diagnostic feature that allows the temperature

selector switches to be tested.
When the temperature selector is changed, the new

setting is displayed by flashing the IN USE LED as

follows:

High/Normal: 4 flashes
Medium/PP: 3 flashes
Low/Delicate: 2 flashes
No Heat: 1 flash

NOTE: To change dipswitch settings refer to

Installation Manual.

To Program a Short Test Cycle:

1. Unplug machine power cord.
2. Write down machine control dip switch settings,

then set them all to the off position. Refer to

Figure 6.

3. Plug machine in and start a cycle.

NOTE: With all control dip switches off, the total

cycle time will be 2 minutes long (1 minute of heat

and 1 minute of cool down).

4. Once all testing is complete, unplug machine and

re-set dip switches to their original settings.

5. Plug machine in.

Figure 6

Error Codes

TMB2216N

1 2 3 4 5 6 7 8

O
N

1

2345

6

78

Display

Definition

Corrective Action

AF (Flashing)

Airflow switch opened/closed 5 or more
times in a running cycle.

Check airflow switch. Replace if inoperative.

To reduce the risk of electric shock, fire, explosion, serious injury or death:

• Disconnect electric power to the tumble dryer before servicing.

• Close gas shut-off valve to gas tumble dryer before servicing.

• Close steam valve to steam tumble dryer before servicing.

• Never start the tumble dryer with any guards/panels removed.

• Whenever ground wires are removed during servicing, these ground wires must be

reconnected to ensure that the tumble dryer is properly grounded.