Operating Instructions

13

70400101 (EN)

Figure 5

Single Drop Control
SD and SX Control Suffixes

1. Select HIGH, MED, LOW or NO HEAT by

turning the temperature knob.
HIGH temperature 190°F (87°C)
MED temperature 160°F (71°C)
LOW temperature 130°F (54°C)

2. Insert the coin(s) in the coin slot.
3. Press START button to start tumble dryer.

IMPORTANT: To stop the tumble dryer at any

time during the cycle, OPEN DOOR. To restart the

tumble dryer, CLOSE door and press START

button.

NOTE: If display show an error code, refer to

Error Codes section.

4. When the cycle is complete, open door and

remove the laundry.

NOTE: This machine includes an extended tumble

feature. Starting 20 minutes after a cycle ends, the

cylinder will tumble for two minutes every hour

without heat, up to 18 hours or until door is

opened.

Preliminary Control Information
Power-Up Mode
When power is applied to the tumble dryer the control

will enter Ready Mode, unless a cycle was in process

prior to a disruption of power. If a power disruption is

less than 5 seconds, with a cycle in process, the control

will enter Run Mode once power is restored and

continue the cycle. If a power disruption is more than

5 seconds, with a cycle in process, the control will

enter Start Mode once power is restored.
If the dry time dipswitch settings have not changed

from the factory default, the IN USE LED will flash

two to five times, depending on model.
Ready Mode
In Ready Mode, the control waits for the vend to be

satisfied before entering Start Mode.
Start Mode
In Start Mode, the vend has been satisfied, but the

Start button has not been pressed. The IN USE LED

will be lit. The timer will not count down until the

Start button is pressed.
Run Mode
In Run Mode, the control is running a cycle. The IN

USE LED is lit.

TMB2120N