Critical messages, Critical messages b-8 – HP NonStop G-Series User Manual

Page 112

Advertising
background image

SDR EMS Messages

HP NonStop SQL DDL Replicator User’s Guide 545799-005

B-8

Critical Messages

Critical Messages

402

Cause. The monitor process has been intentionally abended to produce a saveabend
file for problem diagnosis.

Effect. The primary monitor process abends. The backup process takes over and
continues processing.

Recovery. Send the saveabend file to product support.

403

Cause. An operation was attempted, but no license for that service has been installed.

Effect. The operation is rejected.

Recovery. Obtain and install the necessary license.

407

Cause. The Monitor process and the Runtime have incompatible versions.

Effect. The program abends.

Recovery. Verify that the runtime library and monitor are the same version. Contact
product support for further assistance.

410

Cause. The object file is secured to prevent reading by the user id executing the
process.

Effect. The process abends.

Recovery. Resecure the object file to allow read access.

SDR monitor intentionally abended

Invalid SDR license

Version mismatch between SDR components

Error accessing object file

Advertising
This manual is related to the following products: