Attributes, Actions – HP NonStop G-Series User Manual

Page 176

Advertising
background image

Slot Location: SCSI controllers are located on PMF CRUs in slots 50 and 55 of processor
enclosures and on IOMF CRUs in slots 50 and 55 of I/O enclosures.

Example: SCSI Controller (1.1.55.1)

Attributes

SCSI Controller

Service State

Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK.

Values

Logical

SCSI ID

The ID to which the device answers on the SCSI bus:

4 or 5: Tape devices

6 or 7: Controllers

8 and 9: SCSI extenders/FC converters

The remaining IDs are for the device on the SCSI bus.

SCSI Bus Number

The bus to which the device is attached:

Bus 1 or 2: Internal device

Bus 3: External device

Actions

Responsive Test

Verifies that the component is installed and responding.

SEB

Attributes

Actions

The ServerNet expansion boards (SEBs) and cables allow processors in one enclosure to
communicate with processors in another enclosure. Each SEB CRU provides either the ServerNet X
fabric or the ServerNet Y fabric for a group.

Location in OSM Tree: System > Group > Module > SEB

Slot Location: SEBs must be located in slots 51 and 52 of processor enclosures (service side).

Example: SEB (1.1.52)