Osm guided procedures – HP NonStop G-Series User Manual

Page 20

Advertising
background image

Configuration of remote access (dial-in) and remote notification (dial-out) information

Configuration of dial-out point status for your system console

Specification of the interval at which your OSM server generates periodic incident reports

Authorization (automatically or manually) of incident reports to be dialed out to your service
provider

Note: You can receive and dial out incident reports only from systems for which your system

console is a primary or backup dial-out point.

OSM Guided Procedures

Guided procedures are launched by OSM actions:

OSM Guided Procedure

OSM Action

For Object

Replace PMF, IOMF, SNDA,
SEB, MSEB

Replace

Each CRU

Replace Switch II Component

Replace

HP NonStop Cluster Switch (model
6770) and subcomponents (UPS and
AC transfer switch)

Replace 6780 Switch

Replace

HP NonStop ServerNet Switch (model
6780) and subcomponents (logic board
and PIC)

Replace ServerNet Switch Board
or IOAM Enclosure

For the IOAM Enclosure,
the action is Replace
IOAM Enclosure or
ServerNet Switch Board.

For the ServerNet Switch
Board, the action is
Replace.

IOAM Enclosure and ServerNet
Switch Board

Replace Disk Drive Enclosure
(or component)*

Replace

Disk Drive Enclosure and
subcomponents (Fibre Channel disk
drive, FC-AL I/O module, EMU,
power supply, and blower)

Add Node to ServerNet Cluster
(formerly Configure ServerNet
Node)

Add Node to ServerNet
Cluster

System

* Should be performed only by a trained service provider.

Note: You must be logged on as a super-group user to perform OSM guided procedures.

You can minimize the OSM Service Connection Management window, but must not close
it. If the session you launched the guided procedure from is closed or becomes
disconnected, the guided procedure will close and fail to complete.

Some former TSM guided procedures have been replaced by OSM actions:

TSM Guided Procedure

OSM Action

For Object