Changing the stream configuration

At this time, the Stream Set-up page supports three modes for data streams:

SAP

RSTP

Manual

Each mode has different procedures for setting up the stream configuration, as detailed below.

Setting up an SAP stream configuration

1.

From the Stream Set-up page, choose SAP from the Run Mode drop-down menu. (See FIG. 24.)

2.

Select the server from which the stream originates. If you wish to use the default stream server,
leave the Servers list on Default. If you wish to use a different server, select Other.

3.

If you selected Other on the Servers list, enter the IP address for the new server in the Other Address
field.

4.

Again, if you selected Other on the Servers list, enter the port number in the Other Port field.

5.

If you wish to save the entered information, click the Accept button. If you wish to return to the
previous settings, click Cancel.

Setting up an RTSP stream configuration

1.

From the Stream Set-up page, choose RTSP from the Run Mode drop-down menu. (See FIG. 25)

2.

Select the server out of the servers listed by clicking on the radio button to the left of the server
number.

3.

Enter a new IP addresses, URL, or port number for the selected server in the appropriate field, if
necessary.

4.

To save any changes, click the Accept button on the bottom of the page. To return to the previously
saved information, click Cancel.

5.

After clicking Accept, click the Stream Selector link at the top of the page to open the Stream
Selector
page (page 42).

6.

Select the stream you wish to use and then click the Accept button.

FIG. 25

Stream Configuration Page - RTSP Mode