4 operation, Cleaning models – HP Designjet 3D Printer series User Manual

Page 12

Advertising
background image

8

Chapter 4 Operation

4 Operation

Cleaning Models

Power on the system

Power on the system using the On/Off switch above the power cord receptacle on the back of

the system.

Add models

All models must be placed in the model basket and the model lid adjusted.

The model basket lid ensures the models remain submerged during the cleaning process. The lid

can be adjusted to two heights.

Use the upper lid position for larger models > 8.89 cm (3.5 in.).

Use the lower lid position for smaller size models ≤ 8.89 cm (3.5 in.).

Many models may be cleaned at one time as long as they are submerged during the

cleaning process with the model basket lid in either position.

Delicate and flat models should be placed in the model bag on the model basket lid. When

using the model bag, always select the lower lid position and do not add other models to the

model basket.

Delicate models have features with a cross sectional areas under 19 sq. mm (0.03 sq. in.).

Flat models have large flat areas that are greater than 64 mm x 64 mm (2.5 in x 2.5 in)

and less than 3 mm (1/8 in) thick).

Upper Lid Position

Lower Lid Position