HP Storage EVA Capacity Upgrades User Manual

Page 46

Advertising
background image

46

Event Messages

11

ALERT

A test failure has occurred on the internal SPI bus. This indicates a hardware
failure in the unit. Contact technical support and report the following
information: a receive failure on chip <chip number> has occurred.

12

ALERT

A test failure has occurred on the internal SPI bus. This indicates a hardware
failure in the unit. Contact technical support and report the following
information: a router delivery failure on chip <chip number> has occurred.

13

ALERT

The SPI test has not been run as SPI is not enabled.

14

ALERT

An unknown diagnostics error has occurred. Contact technical support and
report the following information: code <line numbers> chip <number> args
<arguments>.

15

ALERT

An internal error has occurred that will disrupt correct switch operation.
Contact technical support and report the following information: switch chip
<chip number> is not communicating.

16

ALERT

A memory test failure has occurred. This indicates a hardware problem in the
unit. Contact technical support and report the following information: the
address that was detected as failing is <address>.

17

ERROR

An internal error has occurred. Contact technical support and report the
following information: thread <thread number>: <thread number>.

18

EMERGENCY

The temperature inside the box has reached a critical level. The unit will fail to
continue operating if this situation is not resolved. Verify the fans are
operating and are not blocked.

19

ALERT

The temperature inside the box is above normal operating limits. The unit will
continue to operate but this situation should be resolved. Verify the fans are
operating and are not blocked.

20

INFO

The temperature in the unit has returned to normal operating levels.

23

EMERGENCY

Fan 1 has stopped. It has either become jammed or been removed.

24

ALERT

Fan 1 has started.

25

ALERT

Power supply 1 is no longer providing power to the unit. Either AC power has
been removed or the power supply has failed.

26

NOTIFY

Power supply 1 is now delivering power to the unit.

33

NOTIFY

The system time has been changed.

34

NOTIFY

An internal error has occurred while attempting to set the system time. The
time has not been changed.

35

NOTIFY

Loop UP on Port <port number>.

36

NOTIFY

Loop DOWN on Port <port number>.

37

NOTIFY

Port <port number> has logged too many CRC errors. It is being bypassed.

38

NOTIFY

Port <port number> has logged too many ordered set errors. It is being
bypassed.

39

NOTIFY

The speed for port <port number> has been set to <speed setting>.

41

NOTIFY

Network hardware initialization was successful.

42

ERROR

Network hardware initialization has failed.

43

ALERT

An internal error has occurred. Contact technical support and report the
following information: the Ethernet MAC address cannot be located in the
configuration area. Without this information the network hardware cannot be
initialized. Continuing without network support.

44

ERROR

An internal error has occurred. Contact technical support and report the
following information: the Ethernet hardware device could not be initialized.
Continuing without network support.

45

ERROR

The attempt to use DHCP to obtain an IP address has failed. This may
indicate there is no network connectivity or a DHCP server is not available on
the network. The unit will revert to the configured IP information instead.

46

EMERGENCY

System started.

Message

Number

Severity

Description