Port blade compatibility, Setting chassis configurations, Table 17 supported configuration options – HP StorageWorks 2.128 SAN Director Switch User Manual

Page 91: 17 supported configuration options

Advertising
background image

Fabric OS 5.x administrator guide

91

Port blade compatibility

Table 16

indicates which blades are supported for each HP StorageWorks director.

Setting chassis configurations

The

chassisConfig

command allows you to set the chassis configuration for products that support both

single-switch (one domain) and dual-switch (two domains) operation.

Table 17

lists the supported configurations options for Fabric OS 5.x.

Table 16

Blades supported by each HP StorageWorks director

Director

Port Blades
FC-16

FC2-16

FC4-16

FC4-32

Core Switch 2/64

(CP1)

Supported

N/A

N/A

N/A

SAN Director

2/128 (CP2)

Supported

Supported

Supported

N/A

4/256 SAN

Director (CP4)

N/A

Supported

Supported

Supported

Table 17

Supported configuration options

Option Number of

domains

Maximum number

of ports per switch

Supported port

blades

Supported

CP blades

Notes

Results

1

1

128

FC2-16, FC4-16

CP2 or CP4

CP4 fits all chassis

except the D2

chassis. Option 1

is the default

configuration for

the SAN Director

2/128.

One 128-port

switch (Blade

IDs 4, 17 on

slots 1–4, 7–10.

Blade ID 5 and

16 on slots 5, 6)

2

2

64/64

FC2-16

CP2

N/A

Two 64-port

switches (Blade

ID 4 on slots

1–4, 7–10.

Blade ID 5 on

slots 5, 6)

3

2

64/64

Left side: FC2-16

Right side: FC-16

CP2

N/A

Two 64-port

switches (Blade

ID 4 on slots

1–4; ID 2 on

slots 7–10.

Blade ID 5 on

slots 5, 6)

Advertising