HP StorageWorks 2.32 Edge Switch User Manual

Page 217

Advertising
background image

Edge Switch Element Manager user guide 217

Resource is

unavailable.

The specified operation cannot be

performed because the product is

unavailable.

Verify that the HAFM

appliance-to-product link is up. If the

link is up, the HAFM appliance may

be busy. Try the operation again later.

SANtegrity Feature not

installed. Please

contact your sales

representative.

You selected Switch Binding from

the Configure menu, but the

optional SANtegrity Binding

feature is not installed.

Install the SANtegrity Binding key

through the Configure Feature Key

dialog box before using Switch

Binding features.

Send firmware failed.

A firmware download operation

failed.

Retry the firmware download

operation. If the problem persists,

contact the next level of support.

SNMP trap address not

defined.

If an SNMP community name is

defined, a corresponding SNMP

trap recipient address must also be

defined.

Enter a corresponding SNMP trap

recipient address.

Stop diagnostics

failed. The test is

already running.

Diagnostics for the port was not

running and Stop was selected on

the Port Diagnostics dialog box.

Diagnostics for the port quit for

some reason, but the Stop button

remains enabled.

Verify port operation. Retry diagnostics

for the port and select Stop from the

dialog box. If problem persists, contact

the next level of support.

Stop diagnostics

failed. The test was

not running.

This action failed because the test

was not running.

Informational message only—no

action is required

Switch Binding was

removed from attached

devices that are also

participating in Port

Binding. Please review

the Port Binding

Configuration.

The device WWNs were removed

from the director's Switch

Membership List (SANtegrity

Binding feature), but you should

note that one or more of these

devices still has security control in

port binding.

Verify that the security level for each

device is as required by reviewing the

Bound WWN list in the Configure

Ports dialog box.

System diagnostics

cannot run. The

Operational Status is

invalid.

System diagnostics cannot run on

switches with failed ports.

Replace failed ports.

Table 10

Element Manager messages (continued)

Message

Description

Action