Monitoring switch operation

Monitor the operating status of the switch using the switch Status table on the Hardware view and

the status indicator on the status bar at the bottom of the Element Manager window.

Switch Status table

The Status table at the top of the Hardware view displays the switch’s operational status, operational

state, name, description, and location, as follows:

Status—See

Port operational states

” on page 71 for Status symbols and their descriptions.

State—The State field displays one of the following:
Offline—When the switch is

OFFLINE

, all ports are off line. The ports cannot accept a

login from an attached device or cannot connect to other switches. You can configure this

state through the Set on line State dialog box. See ”

Setting online state

” on page 157 for

instructions.

Online—All unblocked ports are able to connect with devices. You can configure the on

line state through the Set Online State dialog box. See ”

Setting online state

” on page 157 for

instructions. Note that the switch automatically goes on line after a power-up, an initial

machine load (IML), or initial program load (IPL).

Coming online—A transitional state that occurs just before the switch goes on line. This

state normally only happens briefly, unless there is a problem reaching the on line state.

Going offline—A transitional state that occurs just before the switch goes off line. This state

normally only happens briefly, unless there is a problem reaching the off line state.

NoLink Status—If the Ethernet network connection between the HAFM appliance, and the

switch is down, the Hardware view displays the front and rear of the unit without FRUs. The

switch Status table at the top of the Hardware view changes to display the status (No Link) and

the associated reason with a yellow background. The name, description, and location fields are

blank.
When the No link is displayed, the Reason field displays one of the following messages:
Never Connected—A network connection was never established between the switch and

the HAFM appliance or the CTP card has failed. Check the IP addresses, the Ethernet local

area network (LAN) physical connection between the switch and HAFM appliance, and

other network connection conditions.

Link Timeout—The network connection that was established between the switch and

HAFM appliance has been lost. Check the IP addresses, the Ethernet LAN physical

connection between the switch and HAFM appliance, IP addresses, and other network

components.

Protocol Mismatch—The switch and the HAFM appliance are not at compatible software

release levels. Update the HAFM software version or your product’s firmware so that they are

at compatible levels.

Duplicate Session—A link has previously been established between the switch and

another instance of the HAFM appliance. Connect to the previously established HAFM

appliance from the HAFM login screen.

Advertising
This manual is related to the following products: