Figure 14 clear threshold alert(s) dialog box, 14 clear threshold alert(s) dialog box – HP StorageWorks 2.32 Edge Switch User Manual

Page 58

Advertising
background image

Monitoring and managing the switch

58

NOTE:

If you click this option button to bind the port to a logged-in device and there are no

devices logged in, the port is essentially bound to a WWN of

0

. This prevents any device from

logging in until this button is re-enabled to bind the WWN of a logged-in device or until you

explicitly bind the WWN of a device by clicking the bound WWN option button and entering a

WWN or nickname (see the following). Changes only take effect when you click the Activate

button.

Detached WWN—Click this option and enter a WWN in the proper format

(

xx.xx.xx.xx.xx.xx.xx.xx

) or a nickname configured through the Product or HAFM.

The device with this WWN or nickname will have exclusive communication privileges

through the port if Port Binding is enabled.
Note the following:
• If you do not enter a valid WWN or nickname in this field, but the Port Binding check

box is checked (enabled), then no devices can communicate over the port.

• If you enter a WWN or nickname in this field and do not place a check in the Port

Binding check box, the WWN or nickname will be stored, and all devices can

communicate over the port.

Activate—Activates settings in this dialog box.

Warning and error messages display under the following circumstances:
• If one or more of the nodes logged into a port does not match the WWN or nickname

configured in the field by the WWN option button, a warning dialog box is displayed

after you activate the configuration. This warning box displays a list of all nodes that will

be logged off if you continue. If you click Continue on the warning box, these nodes

will be logged off and the port will only attach to the device with the WWN or nickname

configured in the WWN field.

• An error message is displayed after you activate the configuration if the format for the

WWN entered in the WWN field is not valid (not in

xx.xx.xx.xx.xx.xx.xx.xx

format) or if you have entered a nickname that was not configured through the Element

Manager.

Clear Threshold Alert(s)—Click this option to display the Clear Threshold Alert(s) dialog

box. Click the appropriate option to clear alerts for the selected port only or for all ports on the

switch. This clears all attention indicators that notify users of threshold alerts in dialog boxes and

views. This action also restarts the notification interval and the cumulative minutes for the

utilization % interval.

Figure 14

Clear Threshold Alert(s) dialog box