Host – HP StorageWorks XP Remote Web Console Software User Manual

Page 36

Advertising
background image

Table 2 Host Mode Options

When to select this option

Host mode options

No.

When VERITAS Database Edition/Advanced Cluster for Real Application Clusters
or VERITAS Cluster Server 4.0 or later (I/O fencing function) is used

VERITAS Database
Edition/ Advanced
Cluster

2

When all the following conditions are satisfied:

The host mode 0C Windows or 2C Windows Extension is used

The Emulex host bus adapter is used

The mini-port driver is used

TPRLO=2 is specified for the mini-port driver parameter of the host bus
adapter

TPRLO

6

When all the following conditions are satisfied:

The host mode 00 Standard or 09 Solaris is used

SUN StorEdge SAN Foundation Software Version 4.2 or better is used

You want to automate recognition of increase and decrease of devices when
genuine SUN HBA is connected

Automatic recognition
function of LUN

7

When all the following conditions are satisfied:

The host mode 08 HP is used

You want to suppress creation of device files for devices to which paths are
not defined.

No display for ghost
LUN

12

When you want to be informed by SIM (service information message) that the
number of link failures detected between ports exceeds the threshold

SIM report at link failure

13

1

When all the following conditions are satisfied:

The host mode 07 Tru64 is used

You want to use TruCluster to set a cluster to each of P-VOL and S-VOL for
XP Continuous Access or HP StorageWorks XP Continuous Access Journal
Software.

HP TruCluster with XP
Continuous Access
function

14

When all the following conditions are satisfied:

The host mode 0F AIX is used

HACMP 5.1 Version 5.1.0.4 or later, HACMP4.5 Version 4.5.0.13 or later,
or HACMP5.2 or later is used

HACMP

15

When Veritas Cluster Server is used.

Veritas Cluster Server

22

When you want to shorten the recovery time on the host side if the data transfer
failed.

REC Command Support

23

1

When all the following conditions are satisfied:

The host mode 03 HP or 05 OpenVMS

2

is used.

You want to enable commands to assign a nickname of the device.

You want to set UUID to identify a logical volume from the host

Set/Report Device
Identifier enable

33

When all the following conditions are satisfied:

The host mode 05 OpenVMS or 07 Tru64 is used

You want to set UUID to identify a logical volume from the host.

UUID Option

34

In case that you want to control the following ranges per host group when
receiving Target Reset:

Range of job resettings

Range of UAs (Unit Attentions) defined

Change the nexus
specified in the SCSI
Target Reset

39

36

Performing LUN Manager Operations

Advertising
This manual is related to the following products: