Enww interpret control-panel messages 193 – HP Color LaserJet Enterprise CP4525 Printer series User Manual

Page 207

Advertising
background image

Description

Recommended action

INCOMPATIBLE FUSER

The incorrect fuser was installed.

CAUTION:

The fuser can be hot while the

product is in use. Wait for the fuser to cool
before handling it.

1.

Open the right door.

2.

Remove the incompatible fuser.

3.

Install the correct fuser.

4.

Close the right door.

INCOMPATIBLE SUPPLIES

For status press OK

Print cartridges or other supply items are
installed that were not designed for this
product. The product cannot print with these
supplies installed.

Press the

OK

button to identify the

incompatible supplies. Install supplies that
are designed for this product.

INCOMPATIBLE TRANSFER UNIT

The incorrect transfer unit was installed.

1.

Open right door.

2.

Remove the incompatible transfer unit.

3.

Install the correct transfer unit.

4.

Close the right door.

Incorrect

The PIN is incorrect.

Use the up arrow and down arrow
buttons to enter the correct PIN.

Initializing

The product is starting.

No action is necessary. Please wait until the
Ready message appears on the display.

Initializing permanent storage

Displayed when the product is turned on to
show that permanent storage is being
initialized.

No action is necessary.

INSTALL <COLOR> CARTRIDGE

The print cartridge has been removed or has
been installed incorrectly.

Replace or reinstall the print cartridge
correctly to continue printing. See

Replace

print cartridges on page 164

.

INSTALL FUSER

The fuser has been removed or installed
incorrectly.

CAUTION:

The fuser can be hot while the

product is in use. Wait for the fuser to cool
before handling it.

1.

Open the right door.

2.

Install or adjust the fuser.

3.

Close the right door.

INSTALL SUPPLIES

For status press OK

More than one supply is missing or is installed
incorrectly.

Press the

OK

button to identify which supplies

need to be replaced. Press the

OK

button a

second time for more information about the
specific supply. Insert the supply item or
make sure the installed supply item is fully
seated.

INSTALL TRANSFER UNIT

The transfer unit has been removed or
installed incorrectly.

1.

Open right door.

2.

Install the transfer unit.

3.

Close the right door.

INSUFFICIENT MEMORY TO LOAD
FONTSDATA

The product does not have enough memory
to load the data (for example, fonts or
macros) from the location specified.

To continue without this information, press
the

OK

button . If the message persists, add

more memory.

Table 10-1

Control-panel messages (continued)

ENWW

Interpret control-panel messages 193

Advertising