Rack chassis numbering – HP ProLiant SL2500 Scalable System User Manual

Page 17

Advertising
background image

Introduction 17

Item

Description

3

HP ProLiant SL Series Chassis

4

HP Moonshot 1500 Chassis

5

Power Distribution Unit

6

HP Intelligent Modular PDU Managed Extension Bar

7

SL APM Distribution Module

When entering commands that require specific port and node numbers, use the HP APM port number, SL
APM Distribution Module port number, and the SL server node number.
For example, to turn on the power for SL server node 3 that is connected to SL APM Distribution Module port
4, which is connected to HP APM port 2, enter the following:
SET POWER ON 2 4 3
where:

2 is the HP APM port.
4 is the SL APM Distribution Module port.
3 is the SL server node.
Parameters must have spaces between them.

NOTE:

HP APM considers the10 Consolidated Management Ports as RDM1.

Rack chassis numbering

If you must number the chassis in your rack or data center, then HP APM can display the chassis numbering,

based on the HP APM Distribution Module port connection.

Item

Description

1

HP APM Distribution Module

2

HP APM connection