CLI commands 82

Set serial

Command:
SET SERIAL <baud rate>

Description:

o

Configure the serial console baud rate.

o

Serial access to the CLI will be by default 115200 bits/s, no parity, 8 data bits, and one stop bit
(“115200 N 8 1”). You can configure these parameters through the CLI.

o

Valid baud rates are 300, 1200, 2400, 4800, 9600, 14400, 19200, and 115200.

Set syslog

Command:
SET SYSLOG {<ip_address>|NONE}

Description:
Sets or clears the sending of HP APM log messages to a remote syslog server. Local logging is
unaffected.

Set time

Command:
SET TIME <month> <day> <year> <hour> <minute>
where:
<month> is the month.
<day> is the day.
<year> is the year.
<hour> is the hour, in 24-hour format. For example, enter 3:00 p.m. as 15.
<minute> is the minute.
HP APM does not automatically adjust for Daylight Savings Time.
The time remains on this setting until you issue the RESET FACTORY command.

Description:

o

Sets the system time on the battery-backed clock.

o

All five parameters must be present. The hour parameter must be in 24-hour format.

Set timeout

Command:
SET TIMEOUT {<timeout_value> | NONE}
where:
<timeout_value> is the session timeout value measured in seconds. For example, to set a 30-second

session timeout, enter: