65

Trigger type input connection menu

This menu tells us to which module a trigger input is connected, and allows us to create a new
connection or delete an existing one. When a trigger input is connected, its graphical aspect
changes, and this tells us if a module is connected without checking the menu:

Trigger input disconnected – Trigger input connected

6.4.6

Synchronization connections

Synchronization connections are used to activate the synchronization of one of the nine
oscillators available to another oscillator.

Synchronization input

The same as for the trigger connectors, here, only the input connectors are visible, the
existence of outputs is implicit, and the connections can only be made through the menus:

Synchronization input connection

6.4.7

Key follow or sequencer connections

The Moog Modular V oscillators generate periodic signals in which the frequency varies in
function with the note played on the keyboard. It is this difference in frequency, which allows
us to recognize two different notes. To determine the ideal frequency related to a note played
on the keyboard, the oscillator refers to a key follow. The function of the key follow is to