Fbwc module led definitions – HP ProLiant DL360e Gen8 Server User Manual

Page 13

Advertising
background image

Component identification 13

Item LED

Status

Definition

Flashing green

The drive is rebuilding or performing a RAID migration, stripe size
migration, capacity expansion, or logical drive extension, or is
erasing.

Flashing
amber/green

The drive is a member of one or more logical drives and predicts
the drive will fail.

Flashing amber The drive is not configured and predicts the drive will fail.

Solid amber

The drive has failed.

Off

The drive is not configured by a RAID controller.

IMPORTANT:

When the SAS-enabled riser board with the Smart Array B320i Controller is

installed in the server, the embedded Smart Array B120i Controller is disabled automatically.
When this condition occurs:

Drives connected to the system board operate in AHCI or Legacy mode.

In AHCI or Legacy mode, drives cannot be a part of a hardware RAID or a logical drive.

The Locate, Drive status, and Do not remove LEDs of the affected drives are disabled.

FBWC module LED definitions

The FBWC module has three single-color LEDs (one amber and two green). The LEDs on the cache module

installed on a storage controller are duplicated on the reverse side of the module to facilitate status viewing.

Cache module installed on a storage controller