Hardware options installation 53

In multiprocessor configurations, each processor must have a valid Lockstep memory mode

configuration.

In multiprocessor configurations, each processor may have a different valid Lockstep memory mode

configuration.

Population order

For Lockstep memory mode configurations with a single processor or multiple processors, populate the DIMM
slots in the following order:

First: B and C

Last: E and F

Do not populate the DIMM slots A and D.
After installing the DIMMs, to configure memory protection mode, use RBSU ("

HP ROM-Based Setup Utility

"

on page

81

).

Installing a DIMM

1.

Power down the server (on page

16

).

2.

Remove all power:

a.

Disconnect each power cord from the power source.

b.

Disconnect each power cord from the server.

3.

Do one of the following:

o

Extend the server from the rack (on page

16

).

o

Remove the server from the rack (on page

17

).

4.

Remove the access panel (on page

18

).

5.

Open the DIMM slot latches.

6.

Install the DIMM.

7.

Install the access panel (on page

19

).

8.

Install the server into the rack ("

Installing the server into the rack

" on page

26

).