Operator control panel

The OCP displays library status information and allows you to access the library menus with a touch

screen. Use these menus to view and change the library settings, move tape cartridges, obtain status

information, or run diagnostic tests. Functions provided by the OCP are:

Robotic and tape drive firmware revision reporting

Library configuration

Library and tape drive serial number reporting

Critical component status report

Critical component failure notification

Ability to move tapes to and from any location

Ability to configure bar code label length and justification reporting to the front panel and to

the host

Access to error information

Adjust screen contrast

10951

3

Figure 16 Location of the OCP

Numbering

All of the tape cartridge slots and tape drives in a library are numbered with a coordinate system.

You might see these numbers in your application software or in error or diagnostic messages. Error

messages often include a slot location in the format MRC x,y,z. This identifies a module (x), row

(y), and column (z) location.
Each module has a different number of available slots, but a common numbering scheme for identifying

the slot location.
The library numbers the LTO slots using the following scheme:

Enterprise Modular Library E-Series

31