Hard drive blank – HP ProLiant ML350 G5 Server User Manual
Page 38
Hardware options installation 38
CAUTION:
To avoid damage to the hard drives, memory, and other system components, the
air baffle, drive blanks, and access panel must be installed when the server is powered up.
1.
Power down the server (on page
2.
Extend the server from the rack (on page
3.
Remove the access panel (on page
4.
Move the hard drive cables.
5.
Remove the air baffle.
6.
Open the FBDIMM slot latches.
7.
Install the FBDIMM.
8.
Install the air baffle.
9.
Install the access panel (on page
10.
If you are installing FBDIMMs in an online spare or mirrored configuration, use RBSU to configure
this feature.
Hard drive blank
To remove a hard drive blank:
1.
Open the bezel (tower model)
2.
Squeeze the tabs to release the blank, and pull the blank out.
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.