Error check, First error check, Second error check – HP StorageWorks XP Remote Web Console Software User Manual

Page 100: First error check second error check

Advertising
background image

Table 19 Available Configuration Values for the [LDEV] Tag (continued)

Available Value

Item

Column

ON or OFF are also available as the set value when you
write the spreadsheet.

Blank

6th, 7th,

16th, 17th

CAUTION:

When the configuration definitions is long, the [LDEV] tag might not be output in the

exporting spreadsheet. Add the LDEV tag and set the command device.

Example of setting the command device:

[LDEV]

00,00,01,Disable ,Disable,,,,,, 00,00,01,Enable,Enable

00,01,01,Disable ,Disable,,,,,, 00,01,01,Enable,Disable

00,02,01,Disable ,Disable,,,,,, 00,02,01,Enable,Disable

00,03,01,Disable ,Disable,,,,,, 00,03,01,Enable,Disable

Error Check

First Error Check

The first error check is performed when the spreadsheet file is imported. The first error check verifies
that the spreadsheet is properly formatted. If there is an error, the spreadsheet is rejected, and an
error message is displayed. Errors detected at this first check include the following:

The first row of the spreadsheet (the declaration line) is not correctly written, or the stated
program product is not installed. For more information on the declaration line, see

(page 90)

.

The spreadsheet file is not in text file format (the file is a binary file).

There is no function tag in the spreadsheet. For more information on the function tag, see

(page 90)

.

The file name is incorrect (for example, the extension is not .spd, or the file name exceeds the
maximum number of letters).

The number of letters in a row exceeds 200.

The number of rows in a spreadsheet exceeds 400,000.

Second Error Check

In the second check, the spreadsheet settings are verified. Any errors found are displayed on the
Error Information list. This second check is performed before the Apply button becomes available.

(page 101)

shows the flow of the second check.

The second error check consists of two different types of the checks. These checks are shown in

(page 101)

as the Level 1 and Level 2. The Level 2 check is performed only when no error is found

by the Level 1 check. Each level of the check of the second error check detects the following errors:

Level 1 check (the format and parameters are checked):

A function tag is not supported.

A setting value is incorrect or omitted.

The setting range is incorrect. The correct ranges are as follows:

LDKC:00

CU:00 - FE

100 Performing LUN Manager Operations Using Configuration File Loader

Advertising