LDEV:00 - FF

LUN: 0000 - 07FF

Group ID: 00 - FE

Host Mode: 00 - 4F

Level 2 check:

The current settings are compared to the imported settings and checked for logical consistency.
Note that certain errors can only be detected by the third check.

When you import a spreadsheet with no errors detected, the window displays Ready above the
error information list, and the Apply button becomes available.

Figure 55 Second Error Check Flow Chart

Third Error Check

The third check is performed after the Apply button is selected. Errors detected at this third check
include the following:

There is no difference between the current configuration definition and the configuration
definition on the imported spreadsheet. The spreadsheet is accepted, but no operation will
be performed.

You are trying to delete a LUN that is needed to process input/output (I/Os).

The errors caused by other factors are detected by the second check as the logical errors of the
settings. However, there could be a case where the current settings are changed even though you
are on the Modify mode. In this case, an error occurs at the third check.

If no errors are found on the third error check, the settings in the spreadsheet are applied to the
storage system.

Error Check