background image

Table 14 SNMP failure trap reference codes (continued)

Alert level

Section

Description

Trap reference code

SIM13

SIM23

SIM22

SERVICE

Failure with paired
volumes

Remote Copy pair status change (MCU Command) (From
Duplex Pending to Suspend(complete))

xx

Ax

D1

SERVICE

Failure with paired
volumes

Remote Copy pair status change (MCU Command) (From
Suspend (continue) to Suspend)

xx

Bx

D1

SERIOUS

Failure with paired
volumes

TC-MF/TC for this volume was suspended (Due to an
unrecoverable failure on the remote copy connections)

xx

0x

D4

SERIOUS

Failure with paired
volumes

TC-MF/TC for this volume was suspended (Due to an
unrecoverable failure on the P-VOL or the remote copy
connections)

xx

1x

D4

SERIOUS

Failure with paired
volumes

TC-MF/TC for this volume was suspended (Due to an
unrecoverable failure on the S-VOL)

xx

2x

D4

SERIOUS

Failure with paired
volumes

TC-MF for this volume was suspended (Caused by DFW
to the S-VOL was prohibited)

xx

3x

D4

SERIOUS

Failure with paired
volumes

TC-MF/TC for this volume was suspended (Due to an
internal error condition detected by the RCU)

xx

4x

D4

SERIOUS

Failure with paired
volumes

TC-MF/TC for this volume was suspended (Caused by
Delete pair operation was issued to the S-VOL)

xx

5x

D4

SERIOUS

Failure with paired
volumes

The S-VOL has suspended. (Due to an unrecoverable
failure on the remote copy connections)

xx

6x

D4

SERIOUS

Failure with paired
volumes

The S-VOL has suspended (Due to an unrecoverable
failure on the S-VOL)

xx

7x

D4

SERIOUS

Failure with paired
volumes

Status of the P-VOL was not consistent with the S-VOL

xx

Fx

D4

SERVICE

Drive

Command device operation execution of command
device in state of ONLINE

xx

7x

D5

SERVICE

Failure with paired
volumes

PAIR VOLUME ESTABLISH

xx

0x

D8

SERVICE

Failure with paired
volumes

COPY START

xx

1x

D8

SERVICE

Failure with paired
volumes

COPY NORMAL END

xx

2x

D8

SERVICE

Failure with paired
volumes

SUSPEND END

xx

3x

D8

SERVICE

Failure with paired
volumes

SUSPEND END

xx

4x

D8

SERVICE

Failure with paired
volumes

PAIR END

xx

5x

D8

SERVICE

Failure with paired
volumes

PAIR END

xx

6x

D8

SERVICE

Failure with paired
volumes

PAIR NORMAL END

xx

7x

D8

SERVICE

Failure with paired
volumes

A Delta volume to be used by the UR was defined

xx

8x

D8

SERVICE

Failure with paired
volumes

A Delta volume to be used by the UR was redefine

xx

9x

D8

SNMP failure trap reference codes