HP XP Racks User Manual

Page 31

Advertising
background image

Table 14 SNMP failure trap reference codes (continued)

Alert level

Section

Description

Trap reference code

SIM13

SIM23

SIM22

SERVICE

Failure with paired
volumes

A change to an S-VOL was received from the RCU (A
pair deletion was completed.)

xx

5x

DA

SERVICE

Failure with paired
volumes

A change to an S-VOL was received from the RCU (An
instruction to delete a pair was received in the Hold
status.)

xx

6x

DA

SERIOUS

Failure with paired
volumes

PAIR SUSPEND(RIO PATH CLOSE)

xx

0x

DC

SERIOUS

Failure with paired
volumes

PAIR SUSPEND(MVOL ERROR)

xx

1x

DC

SERIOUS

Failure with paired
volumes

PAIR SUSPEND(RVOL ERROR)

xx

2x

DC

SERIOUS

Failure with paired
volumes

PAIR SUSPEND(SUSPEND REPORT)

xx

4x

DC

SERIOUS

Failure with paired
volumes

PAIR SUSPEND(SIMPLEX REPORT)

xx

5x

DC

SERIOUS

Failure with paired
volumes

PAIR SUSPEND(COMMUNICATION ERROR AT RCU)

xx

6x

DC

SERIOUS

Failure with paired
volumes

PAIR SUSPEND(ERROR DETECTED AT RCU)

xx

7x

DC

SERVICE

Failure with paired
volumes

A volume being used by an S-VOL was suspended (PS
OFF on the MCU side was detected)

xx

8x

DC

SERIOUS

Failure with paired
volumes

ERASE FAIL

xx

9x

DC

SERIOUS

Failure with paired
volumes

Pair suspend (Spread by error of another Affiliate)

xx

Ax

DC

MODERATE

Failure with paired
volumes

UR M-JNL Meta overflow warning

xx

E0

DC

MODERATE

Failure with paired
volumes

UR M-JNL Data overflow warning

xx

E1

DC

MODERATE

Failure with paired
volumes

UR R-JNL Meta overflow warning

xx

E2

DC

MODERATE

Failure with paired
volumes

UR R-JNL Data overflow warning

xx

E3

DC

MODERATE

Failure with paired
volumes

The UR Read JNL was interrupted for one minute (A
failure on the MCU side was detected)

xx

F0

DC

SERIOUS

Failure with paired
volumes

The UR Read JNL was interrupted for five minutes (A
failure on the MCU side was detected)

xx

F1

DC

MODERATE

Failure with paired
volumes

The UR Read JNL was interrupted for one minute (A
failure on the RCU side was detected)

xx

F2

DC

SERIOUS

Failure with paired
volumes

The UR Read JNL was interrupted for five minutes (A
failure on the RCU side was detected)

xx

F3

DC

MODERATE

Failure with paired
volumes

URxUR M-JNL Meta full Warning

xx

F4

DC

MODERATE

Failure with paired
volumes

URxUR M-JNL Data full Warning

xx

F5

DC

SNMP failure trap reference codes

31