Operands, Example, 151 example – HP XP Array Manager Software User Manual

Page 151

Advertising
background image

Operands

The value on the left of the colon (:) specifies the starting time of the period. The value on the right of
the colon specifies the ending time of the period. Specify the term within Long Range From XXX
To XXX

which is output by the show command.

If no value is specified on the left of the colon, the starting time for collecting monitoring data is
assumed. If no value is specified on the right of the colon, the ending time for collecting monitoring
data is assumed. The starting and ending times for collecting monitoring data are displayed in the
Monitoring Term area in the Auto LUN window (see

Figure 48

).

Figure 48 Starting and Ending Time for Collecting Monitoring Data

.

Description

Operand

yyyyMMdd indicates the year, the month, and the day. hhmm indicates the hour and
the minute.
If yyyyMMddhhmm is omitted on the left of the colon, the starting time for collecting
monitoring data is assumed. If yyyyMMddhhmm is omitted on the right of the colon, the
ending time for collecting monitoring data is assumed.

yyyyMMddhhmm

Adds time (ddhhmm) to yyyyMMddhhmm if yyyyMMddhhmm is specified. For example,
200601120000+010130 indicates Jan. 13, 2006. 01:30.
Adds time to the starting time for collecting monitoring data, if yyyyMMddhhmm is
omitted.

+ddhhmm

Subtracts time (ddhhmm) from yyyyMMddhhmm if yyyyMMddhhmm is specified. For
example, 200601120000-010130 indicates Jan. 10, 2006. 22:30.
Subtracts time from the ending time for collecting monitoring data, if yyyyMMddhhmm
is omitted.
Ensure that mm is 00, 15, 30, or 45. If you do not specify mm in this way, the value
on the left of the colon (:) will be rounded down to one of the four values. Also, the
value on the right of the colon will be rounded up to one of the four values. For example,
if you specify 200601010013:200601010048, the specified value is regarded as
200601010000:200601010100.

-ddhhmm

Example

The examples below assume that:

The starting time for collecting monitoring data is Jan. 1, 2006, 00:00.

The ending time for collecting monitoring data is Jan. 2, 2006, 00:00.

longrange 200601010930:2004601011730

XP24000/XP20000 Performance Monitor User Guide