HP ProLiant Support Pack User Manual

Page 17

Advertising
background image

Introduction 17

Component

Supported

Mellanox NIC firmware

Yes

Power Management Controller firmware

Yes

Smart Array Controller firmware

Yes

SAS and SATA hard drive firmware behind Smart Array

controllers

Yes

SAS and SATA hard drive firmware behind non-Smart Array
controllers

No

Emulex, QLogic, and Brocade Fibre Channel Host Bus Adapter
firmware

Yes, offline only

Tape blade firmware

Yes

Virtual Connect firmware*

Yes, online only

HP StorageWorks 600 Modular Disk System (MDS600)**

Yes, offline only

HP 3Gb SAS BL Switch firmware***

No

Onboard Administrator Firmware****

Yes, online only

HP Workstation WS460c G6 Blade ROM

Yes, offline only

HP ProLiant Blade Servers ROM

Yes

HP ProLiant 100 Series Servers ROM

Yes

When updating HP ProLiant blade servers in an HP BladeSystem Matrix, do not select ftp.hp.com to

download the latest components. Ensure the component source contains versions of components that match
the BladeSystem Matrix Compatibility chart before using HP SUM to deploy any software of firmware.
To view the BladeSystem Matrix compatibility chart, see www.hp.com/go/matrixcompatibility

(

http://www.hp.com/go/matrixcompatibility

).

*Virtual Connect firmware components can also be downloaded from the HP website and they can be

added to the HP Smart Update Firmware DVD by creating a USB key using the USB Key Utility. The latest
version can be obtained from the HP BladeSystem Firmware Maintenance website
(

http://www.hp.com/go/bladesystemupdates

).

HP SUM 4.0.2 and earlier only support deploying Virtual Connect firmware components version 2.3x and
earlier. If you must deploy a later version of Virtual Connect firmware, you must use VCSU which is provided

with the component.
**MDS600 firmware update requires HP SUM 3.6.0 or later. All blades in an enclosure with Smart Array

P700M controllers, except the blade doing the update, must be turned off before the firmware update
process is initiated. MDS600 firmware can only be updated using the HP Smart Update Firmware DVD in
offline mode.
***The HP 3Gb SAS BL Switch firmware can only be updated by uploading a bin file through the VSM

product. This firmware is currently delivered as a binary image file on the HP website and must be
downloaded and manually upgraded.
Because firmware might be able to update only in online or offline mode for some components, you might
need to execute the HP Smart Update Firmware DVD both online and offline to update all the firmware in an
enclosure.
****Downgrading the Onboard Administrator firmware from a new major release to an older release
version (for example, 3.x to 2.x) is not supported in HP SUM. Downgrading to a minor version from within a

major version is supported (for example, 2.60 to 2.52). To manually install a previous version of the

Advertising