HP ProLiant Support Pack User Manual

Page 69

Advertising
background image

Scripted deployment 69

Command-line
argument

Description

/target "netAddress"

This argument is the IP address or the DNS name of a remote server, remote

iLO NIC port, Virtual Connect Ethernet or Fibre Channel Module for c-Class
BladeSystem, or BladeSystem Onboard Administrator.
When two Onboard Administrators are in an enclosure, this argument should
be the active Onboard Administrator. When specifying the IP address, you
can use either the IPv4 or IPv6 format.

Log files

/logdir "path"

This argument enables you to redirect the output from HP SUM or the HP

BladeSystem c-Class Onboard Administrator flash utility to a different

directory than the default location.

For Windows® components, the default location is

%SYSTEMDRIVE%\CPQSYSTEM\hp\log<netAddress> and the redirected
location is <path>\hp\log\<netAddress>.

For Linux components, the default location is /var/hp/log/<netAddress>

and the redirected location is <path>/hp/log/<netAddress>.

/v[erbose] or

/veryv[erbose]

These arguments enable you to set the verbosity level for the HP SUM
execution log file, hpsum_execution_log_<date>_<time>.log. Using one of

these arguments increases the level of detail that is retained in the log file.
The default value is normal verbosity.

Generating reports
/report

This argument generates a report listing, a target summary, and how the

components in the repository affect the target (For example, whether each
component applies to the target or not). The report name is of the format,
HPSUM_ Report_<date>_<time>.html.
By default, it is located in the present working directory where HP SUM is
initiated from. If that location is write-protected, the report can be found in the

same directory as the HP SUM log files. (This CLI does not apply to firmware
updates on the HP Integrity BL860c/BL870c/BL890c i2 Servers.)

/inventory_report

This argument generates a report listing of the components in the specified
repository. The report name is of the format,

HPSUM_Inventory_Report_<date>_<time>.html.
By default, it is located in the present working directory where HP SUM is

initiated from. If that location is write-protected, the report can be found in the
same directory as the HP SUM log files. (This CLI does not apply to firmware
updates on the HP Integrity BL860c/BL870c/BL890c i2 Servers.)

/firmware_report

This argument generates a report listing of the firmware in the specified
repository. The report name is of the format,

HPSUM_Firmware_Report_<date>_<time>.html.
By default, it is located in the present working directory where HP SUM is

initiated from. If that location is write-protected, the report can be found in the
same directory as the HP SUM log files. (This CLI does not apply to firmware
updates on the HP Integrity BL860c/BL870c/BL890c i2 Servers.)

Using input files

/inputfile “filename”

This argument enables you to script the deployment of firmware and software
to multiple remote systems at one time. For details of the file format and

commands, see the "Input files" section.

/Delete input file

This argument enables you to instruct HP SUM to delete the input file after it

Advertising
This manual is related to the following products: