Cannot configure datastore block size – HP OneView for VMware vCenter User Manual

Page 125

Advertising
background image

Action: LUNs with the same disk names are duplicates and represent a single disk on the storage
array.

Storage Administrator Portal information cannot be exported

Possible cause: The required ActiveX controls are disabled.

Action: To export data from the Storage Administrator Portal, enable the following ActiveX controls
in Internet Explorer:

Download unsigned ActiveX controls

Initialize and script ActiveX controls not marked as safe for scripting

Script ActiveX controls marked as safe for scripting

NOTE:

Some third-party security software may prevent you from enabling and saving these

ActiveX control settings. If you change these ActiveX control settings and they revert to the default
settings, check your security software and local security policy.

See your Microsoft documentation for more information about Internet Explorer security settings.

Internet Explorer script error occurs in environment with 100 or more LUNs

The following message occurs during a refresh in an environment with 100 or more LUNs:

Stop running this script? A script on this page is causing
Internet Explorer to run slowly. If it continues to run, your computer might
become unresponsive.

Possible cause: An Internet script is taking too long to complete.

Action: Click No.

Action: Add or modify the registry entry.
1.

Open the registry key HKEY_CURRENT_USER\Software\Microsoft\Internet
Explorer\Styles

. If the key does not exist, add it.

2.

Create a DWORD value called MaxScriptStatements under the key you opened or
created in

Step 1

.

3.

Assign the value 0x00FFFFFFFF to prevent the script error. To prevent Internet Explorer from
displaying this error message again, use the value 0xFFFFFFFF.

HP MSA virtual disks displayed as local or unmanaged disks

Virtual disks from a HP MSA array are displayed as local or unmanaged disks.

Cause: The Storage Module for vCenter does not display information about MSA SAS disks.

Cannot configure datastore block size

You cannot configure the block size for the VMFS-5 file system when creating a datastore in an
vSphere 5.x/ESXi 5.x environment.

Cause: When creating datastores using the VMFS-5 file system, VMware does not support values
other than 1 MB for the block size.

Cannot configure HP MSA array when using user-created account

When configuring HP MSA arrays, an Unable to Authenticate error occurs.

Cause: The WBI does not include an option to enable SMI-S when a new user is created. It has
an option to enable FTP, CLI, and WBI only. This is a WBI limitation.

Action: Use the CLI with the manage option to create the user.

For example:create user newUser level manage interfaces cli, ftp, smis,
wbi password password

Troubleshooting the Storage Module for vCenter

125