For v-vols, Tier properties table when selecting a thp v-vol – HP XP Racks User Manual

Page 367

Advertising
background image

The following table describes these items.

Description

Item

The capacity (GB) of the area from the dot of the maximum value on the vertical
scale to a specified dot. The capacity of the dot on the vertical scale is 0.00 GB.

Capacities

All I/Os are sorted into 127 sections. The average I/O is the representative I/O
number assigned to each section, based on the definition of the storage system.
By the total number of I/Os, the number of dots may be 127 or less.

Average I/Os

The total number of I/Os in the section from the dot of the maximum value on the
vertical scale to a specified dot. The total I/Os is calculated using the average

Total I/Os

I/Os and capacities in the specified section. If the specified dot is on the vertical
scale, the total I/Os is zero.

When no I/Os are in the lower tier with multiple tiers, the tier range line is placed at 0 on the
vertical scale.
For example, if the dot is placed far from the lower limit of the tier range, the lower limit levels of
the Tier 1 Range and Tier 2 Range are adjusted to improve the visibility of the performance graph.
In this case, the value that is obtained by RAID Manager may not correspond with the value of the
dot displayed in a performance graph.

For V-VOLs

The following table provides the View Tier Properties table information when LDEV information is
present.

Tier Properties table when selecting a THP V-VOL

Description

Item

Displays the combination of the LDKC, CU, and LDEV.

LDEV ID

Displays the LDEV name.

LDEV name

Displays the tiering policy name and ID.

Tiering Policy

Displays the new page assigned tier.

New Page Assignment Tier

Displays whether tier relocation is set to Enabled or Disabled.

Tier Relocation

Displays the relocation priority.

Relocation Priority

Displays the tier names: Tier1, Tier2, Tier3, and Total. Each column displays
information about the tier.

Tier name

Displays the data drive type and RPM of tier.

Drive Type/RPM

If multiple types exist in a tier, Mixed is displayed. For an external volume, Drive
Type displays External Storage with the value of the external LDEV tier rank.

Displays the total capacity of each tier and total capacity of the pool.

Pool Capacity

Displays the percentage of the used capacity for the pool and each tier. The
field is updated asynchronously with the Recent Tier Utilization table and when

Used Capacity (Used %)

the View Tier Properties window is opened. The Used Capacity of each tier may
differ from the Total value.

View Tier Properties window 367

Advertising
This manual is related to the following products: