Managing logical units workflow, Configuring hosts and fibre channel ports – HP XP Racks User Manual

Page 166

Advertising
background image

Restrictions

You cannot define an LU path to journal volumes.

You cannot define an LU path to pool volumes.

When defining LU paths, you must not use RAID Manager and Remote Web Console at the
same time. If both programs are used simultaneously, operations may not be performed in
the expected order and the storage configuration might be defined incorrectly.

Guidelines

If you attempt to apply many settings in the LUN Manager windows, the SVP might be unable
to continue processing. Therefore, you should make nor more than approximately 1,000
settings. Note that many settings are likely to be made when defining alternate paths (see

“Defining alternate LU paths” (page 179)

), even though only two commands are required for

defining alternate paths.

Do not perform the following when host I/O is in progress and hosts are in reserved status
(mounted):

Remove LU paths (see

“Deleting LU paths” (page 181)

)

Disable LUN security on a port (see

“Disabling LUN security on a port” (page 185)

)

Change the data transfer speed for Fibre channel ports

Change AL-PAs or loop IDs

Change settings of fabric switches

Change the topology

Change the host modes

Remove host groups

Setting command devices

Managing logical units workflow

1.

Configure fibre channel ports

2.

Configure hosts

3.

Configure LU paths

4.

Enable LUN security

5.

Set fibre channel authentication

6.

Manage hosts

Configuring hosts and fibre channel ports

When provisioning your system, configure hosts and fibre channel ports using LUN Manager. You
can manage hosts, modify the host configuration, and modify the port configuration when the
system is in operation.

“Configuring fibre channel ports” (page 167)

“Configuring hosts” (page 169)

166 Managing logical volumes

Advertising